APC Smart-UPS X 3000VARack/Tower LCD 100-127V
EAN: 731304268550
The APC Smart-UPS X 3000VARack/Tower LCD 100-127V provides a continuous supply of battery power for connected devices in the event of an AC power loss. It also safeguards equipment from surges, spikes, lightning, and electrical disturbances. An on-board LCD display, available in multiple languages, gives you a comprehensive and precise readout on critical system functionality. Aunique feature of this UPS is green mode which, by bypassing unused electrical components in good power conditions, saves energy costs while reducing the impact on the environment.
This UPS incorporates a notification process which will let you know the month and year that the battery is recommended for replacement so you can plan ahead of time. The system will also notify you if it detects a problem with the battery so you can take the proper measures before it fails completely. Thanks to hot-swap support you can replace the battery on the fly without interrupting the UPS surge protection functionality.
This UPS features a USB connection that enables configuration and control from a PC. It also has a Smart-Slot for integrating the UPS into a network for remote accessibility. There s also an Automatic Voltage Regulator (AVR) which ensures clean and uninterrupted AC power by correcting low and high voltage conditions without using the battery.
This UPS features an intelligent battery management that prolongs battery life by using a charging method that takes into account the battery s age, capacity, temperature, and other factors. An automatic self-test function periodically checks the efficiency of the battery and provides notification when the battery is nearing the end of its usefulness. If the battery requires replacement it can be done easily without the need for tools. The system will also notify you if the battery is disconnected. An LED indicator lets you see at a glance power and battery status. The UPS also features an automatic restart function which will automatically power up devices after AC is restored.
System
Intuitive LCD Interface
Provides clear and accurate information in multiple languages with the ability to configure the UPS locally with easy to use navigation keys.
High Frequency Design
Reduces or eliminates bulky transformers resulting in lighter units for ease of handling.
Auto Recognition of External Batteries
UPS recognizes when external battery packs are attached and automatically adjusts runtime.
Predictive Replace Battery Date
Dynamically provides the month and year when battery replacement is recommended to aide in long term maintenance planning.
Green Mode
Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.
Energy Meter
Provides actual kilowatt hours of usage for energy conscious users.
Outlet Group Control
Turn on/off, reboot or shut down select outlet groups to save dispatching technicians to remote locations (for UPSs with switched outlet groups).
Sequenced Shutdown and Restart
Configure select outlet groups to shut down and turn on in a pre-determined order (for UPSs with switched outlet groups).
Load Shedding
Turn off select outlet groups in a pre-determined sequence to shed less critical equipment and conserve runtime (UPSs with switched outlet groups).
InfraStruXure Central Compatible
Enables centralized management via APC InfraStruXure Central.
Pure Sine Wave Output on Battery
Simulates utility power to provide the highest degree of compatibility for active PFC (power factor corrected) servers and sensitive electronics.
Multiple Switched Outlet Groups
Multiple outlet groups that may be controlled separately from the UPS for discrete reboot of hung devices, sequenced on/off and non-critical load shedding.
Wide Input Voltage Range
Designed for harsh electrical environments to save battery life.
Battery Failure Notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance.
High Online Efficiency
Reduces utility costs, generates less heat.
LED Indicators
Provide easy-to-read status of the unit and utility power conditions.
Overload Protection
Safeguards unit from damage by automatically turning it off in the event of a short circuit or overload.
SmartSlot
Customize UPS capabilities with management cards.
Cold-Start Capable
Provides temporary battery power when the utility power is out.
Hot-Swappable Batteries
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced.
Disconnected Battery Notification
Warns when a battery is not available to provide backup power.
Automatic Self-Test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Automatic Restart of Loads After UPS Shutdown
Automatically starts up the connected equipment upon the return of utility power.
Adjustable Voltage-Transfer Points
Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.
Adjustable Voltage Sensitivity
Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.
Audible Alarms
Provides notification of changing utility power and UPS conditions.
User-Replaceable Batteries
Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR).
USB Connectivity
Provides management of the UPS via a USB port (not available on all models).
Serial Connectivity
Provides management of the UPS via a serial port.
Temperature-Compensated Battery Charging
Prolongs battery life by regulating the charge voltage according to battery temperature.
Boost and Trim Automatic Voltage Regulation (AVR)
Gives higher application availability by correcting low and high voltage conditions without using the battery.
Scalable Runtime
Allows additional run time to be quickly added as needed.
Intelligent Battery Management
Maximizes battery performance, life, and reliability through intelligent, precision charging.
Safety-Agency Approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
Rack/Tower Convertible
Protects the initial investment in the UPS when migrating from tower to rack-mount environment.
Network Manageable
Provides remote management of the UPS over the network.
Frequency and Voltage Regulation
Gives higher application availability by correcting poor frequency and voltage conditions without using the battery.
Predicitive Failure Notification
Availability
Boost and Trim Automatic Voltage Regulation (AVR)
Gives higher application availability by correcting low and high voltage conditions without using the battery.
Intelligent Battery Management
Maximizes battery performance, life, and reliability through intelligent, precision charging.
Power Conditioning
Protects connected loads from surges, spikes, lightning, and other power disturbances.
Temperature-Compensated Battery Charging
Prolongs battery life by regulating the charge voltage according to battery temperature.
Automatic Restart of Loads After UPS Shutdown
Automatically starts up the connected equipment upon the return of utility power.
Automatic Self-Test
Period
EAN: 731304268550
The APC Smart-UPS X 3000VARack/Tower LCD 100-127V provides a continuous supply of battery power for connected devices in the event of an AC power loss. It also safeguards equipment from surges, spikes, lightning, and electrical disturbances. An on-board LCD display, available in multiple languages, gives you a comprehensive and precise readout on critical system functionality. Aunique feature of this UPS is green mode which, by bypassing unused electrical components in good power conditions, saves energy costs while reducing the impact on the environment.
This UPS incorporates a notification process which will let you know the month and year that the battery is recommended for replacement so you can plan ahead of time. The system will also notify you if it detects a problem with the battery so you can take the proper measures before it fails completely. Thanks to hot-swap support you can replace the battery on the fly without interrupting the UPS surge protection functionality.
This UPS features a USB connection that enables configuration and control from a PC. It also has a Smart-Slot for integrating the UPS into a network for remote accessibility. There s also an Automatic Voltage Regulator (AVR) which ensures clean and uninterrupted AC power by correcting low and high voltage conditions without using the battery.
This UPS features an intelligent battery management that prolongs battery life by using a charging method that takes into account the battery s age, capacity, temperature, and other factors. An automatic self-test function periodically checks the efficiency of the battery and provides notification when the battery is nearing the end of its usefulness. If the battery requires replacement it can be done easily without the need for tools. The system will also notify you if the battery is disconnected. An LED indicator lets you see at a glance power and battery status. The UPS also features an automatic restart function which will automatically power up devices after AC is restored.
System
Intuitive LCD Interface
Provides clear and accurate information in multiple languages with the ability to configure the UPS locally with easy to use navigation keys.
High Frequency Design
Reduces or eliminates bulky transformers resulting in lighter units for ease of handling.
Auto Recognition of External Batteries
UPS recognizes when external battery packs are attached and automatically adjusts runtime.
Predictive Replace Battery Date
Dynamically provides the month and year when battery replacement is recommended to aide in long term maintenance planning.
Green Mode
Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.
Energy Meter
Provides actual kilowatt hours of usage for energy conscious users.
Outlet Group Control
Turn on/off, reboot or shut down select outlet groups to save dispatching technicians to remote locations (for UPSs with switched outlet groups).
Sequenced Shutdown and Restart
Configure select outlet groups to shut down and turn on in a pre-determined order (for UPSs with switched outlet groups).
Load Shedding
Turn off select outlet groups in a pre-determined sequence to shed less critical equipment and conserve runtime (UPSs with switched outlet groups).
InfraStruXure Central Compatible
Enables centralized management via APC InfraStruXure Central.
Pure Sine Wave Output on Battery
Simulates utility power to provide the highest degree of compatibility for active PFC (power factor corrected) servers and sensitive electronics.
Multiple Switched Outlet Groups
Multiple outlet groups that may be controlled separately from the UPS for discrete reboot of hung devices, sequenced on/off and non-critical load shedding.
Wide Input Voltage Range
Designed for harsh electrical environments to save battery life.
Battery Failure Notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance.
High Online Efficiency
Reduces utility costs, generates less heat.
LED Indicators
Provide easy-to-read status of the unit and utility power conditions.
Overload Protection
Safeguards unit from damage by automatically turning it off in the event of a short circuit or overload.
SmartSlot
Customize UPS capabilities with management cards.
Cold-Start Capable
Provides temporary battery power when the utility power is out.
Hot-Swappable Batteries
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced.
Disconnected Battery Notification
Warns when a battery is not available to provide backup power.
Automatic Self-Test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Automatic Restart of Loads After UPS Shutdown
Automatically starts up the connected equipment upon the return of utility power.
Adjustable Voltage-Transfer Points
Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.
Adjustable Voltage Sensitivity
Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.
Audible Alarms
Provides notification of changing utility power and UPS conditions.
User-Replaceable Batteries
Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR).
USB Connectivity
Provides management of the UPS via a USB port (not available on all models).
Serial Connectivity
Provides management of the UPS via a serial port.
Temperature-Compensated Battery Charging
Prolongs battery life by regulating the charge voltage according to battery temperature.
Boost and Trim Automatic Voltage Regulation (AVR)
Gives higher application availability by correcting low and high voltage conditions without using the battery.
Scalable Runtime
Allows additional run time to be quickly added as needed.
Intelligent Battery Management
Maximizes battery performance, life, and reliability through intelligent, precision charging.
Safety-Agency Approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
Rack/Tower Convertible
Protects the initial investment in the UPS when migrating from tower to rack-mount environment.
Network Manageable
Provides remote management of the UPS over the network.
Frequency and Voltage Regulation
Gives higher application availability by correcting poor frequency and voltage conditions without using the battery.
Predicitive Failure Notification
Availability
Boost and Trim Automatic Voltage Regulation (AVR)
Gives higher application availability by correcting low and high voltage conditions without using the battery.
Intelligent Battery Management
Maximizes battery performance, life, and reliability through intelligent, precision charging.
Power Conditioning
Protects connected loads from surges, spikes, lightning, and other power disturbances.
Temperature-Compensated Battery Charging
Prolongs battery life by regulating the charge voltage according to battery temperature.
Automatic Restart of Loads After UPS Shutdown
Automatically starts up the connected equipment upon the return of utility power.
Automatic Self-Test
Period
APC 3000VA Specs
General
Total Outlets | 3 x NEMA 5-15R 3 x NEMA 5-20R 1 x NEMA L5-20R |
Plug Type | NEMA L5-30P |
SmartSlot Interface | 1 |
Data Line Protection | RJ45 |
Communications | Serial via RJ45 USB via Type-B |
Emergency Power Off (EPO) Support | Yes |
Topology | Line Interactive |
Transfer Time | 2 to 4 ms |
Power
Surge Energy Rating | 540 Joules |
Maximum Wattage | 2700 W |
Nominal Input Voltage | 240 VAC |
Input Frequency | 50/60 Hz ± 3 Hz (Auto Sensing) |
Nominal Output Voltage | 240 VAC |
Output Frequency | 50/60 Hz ± 3 Hz |
Voltage Distortion | <5% |
Load Capacity | 3000 VA |
Thermal Dissipation | 276 BTU/Hour |
Maximum Efficiency | 98% |
Waveform | Sine Wave |
Battery
Cells | 1 |
Chemistry | Lead-Acid |
Full-Load Runtime | 6 Minutes |
Recharge Time | 3 Hours |
Replacement Battery | APCRBC117 |
Environmental
Operating Temperature | 32 to 104°F / 0 to 40°C |
Operating Humidity | 0 to 95% |
Storage Temperature | 5 to 113°F / -15 to 45°C |
Storage Humidity | 0 to 95% |
Operating Altitude | 10,000` / 3000 m |
Storage Altitude | 50,000` / 15,000 m |
Noise Level | 55 dBA |
Certifications | RoHS *as per Manufacturer |
Physical
Cable Length | 8` / 2.4 m |
Rackmount Size | 2 RU (with Included Hardware) |
Dimensions (W x H x D) | 3.4 x 17 x 26.3" / 85 x 432 x 667 mm |
Weight | 84.6 lb / 38.5 kg |
Packaging Info
Package Weight | 97.2 lb |
Box Dimensions (LxWxH) | 33 x 23.5 x 9.5" |
In the Box
- APC Smart-UPS X 3000VA Rack/Tower LCD 100-127V
- CD with Software
- Documentation CD
- Installation Guide
- Rack Mounting Brackets
- Rack Mounting Hardware
- Rack Mounting Support Rails
- Removable Support Feet
- Smart UPS Signaling
- Smart-UPS Signaling RS-232 Cable
- RS-232 Cable
- USB Cable
- 3 Years Repair or Replace (excluding battery) and 2 Years for Battery
No posts found