SolarEdge Energy Meter SE-MTR-3Y-400V-A with 3x 100A converter
with Modbus connection for SolarEdge systemsExpansion of existing system PV to StorEdge
- High accuracy of meter readings for production/consumption monitoring
- Read out feed and reference for feed limitation
- Small size and easy installation - suitable for standard distributors
- Suitable for systems on residential houses, commercial buildings or large PV systems
- Integrated bus terminating resistor (can be activated / deactivated via DIP switch 7)
Technical data SE-MTR-3Y-400V-A
0.525 kg
EAN: 4262431421823
ELECTRICAL DATA | |
operating voltage range - outer conductor to neutral / outer conductor to outer conductor: | Nominal: 230/400 Vac 184-264.5 / 320-460 Vac |
AC frequency: | 45/65 Hz |
Supported networks - single-phase; three-phase (3): | L / N / PE ; L1 / L 2 / L3 / N / PE |
power consumption (typ.): | 3 W |
current converter inputs CCT Inputs: | 333 mV |
COMMUNICATIONS | |
Supported communication interfaces: | RS485 half-duplex, 3 cables (A, B, GND) |
Reaction time: | ≤200ms(4) |
Preset device ID (Modbus): | 2 |
terminating resistor for RS485: | 120 Ω |
ACURACY (AT 25 °C, POWER FACTOR: 1) | |
1 % - 100 % of the current transformer rated current: | ±1.0 % |
ERFÜLLTE STANDARDS | |
operating temperature range safety: | IEC 61010-1, UL 61010-1, CAN/CSA-C22.2 No. 61010-1-04, |
Resistance: 2000, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6 | |
EMV: | EN 55022 Class B |
MECHANICAL SPECIFICATIONS | |
Dimensions: | 75 x 138.6 x 35 mm |
Weight: | 225 g |
Type of use: | |
operating temperature range: | -40 to +85 °C |
Relative humidity (non-condensing): | 310 g |
Mounting type: | DIN rail / wall mounting |
current converter | |
model(4): | SECT-SPL-100A-A |
Quantity: | 3 |
rated current (RMS): | 100 A |
dimensions (inner / outer): | 9 x 9 mm / 30.5 x 23.2 x 42.4 mm |
(3) PE connection (protective earth) is not required for meter operation
(4) If the meter is connected to the grid connection point and if RS485 is used for several inverters
For further details please refer to the data sheet.