Jensen Transformers Iso-Max DIN-LOD 1-Channel Line Output Isolator (Extra-High Output, DIN Rail)

Jensen Transformers, Condition:New, MPN:DIN-LOD
132.79
14 Days
Price in points: 133 points
Reward points: 1 point
JEDINLOD
In stock
+

Minimum quantity for "Jensen Transformers Iso-Max DIN-LOD 1-Channel Line Output Isolator (Extra-High Output, DIN Rail)" is 1.

Item ships within 3 days, Shipping from european distribution center, Free delivery all over Europe, New product, Local european warranty, 14 Day money back guarantee
Shipping time and rates:
Yes, we can ship to United States
Jensen Transformers Iso-Max DIN-LOD 1-Channel Line Output Isolator (Extra-High Output, DIN Rail)

EAN: 676101041763

Ideal for use in performance venues, broadcast houses, and broad-scale A/V installations, the Jensen Transformers Iso-Max DIN-LOD is a passive, single-channel line output isolator designed to drive balanced and unbalanced audio signals over long distances, while eliminating hum caused by ground loops. The unit is plug-and-play with no power required, and snaps into place onto a standard 35mm DIN rail, for easy installation in a NEMA electrical enclosure.

The DIN-LOD features a high-performance Jensen transformer with internal Faraday shield that isolates the input from the output to reduce common-mode noise by as much as 110 dB. Furthermore, a choice of connection point options allows you to optimize the grounding circuitry to suit your specific installation needs. The unit is capable of withstanding input levels in excess of +22 dB at 20 Hz, without discernible distortion. It delivers an extra-high output level of +22 dBu with a flat frequency response from 2 Hz to 100 kHz.

Connections to and from the Iso-Max DIN-LOD are made via removable screw-down wire terminals. The module comes equipped with a gray molded assembly made from UL94-VO flame-retardant Noryl.

Key Features

  • Passive, single-channel line output isolator for broadcast, A/V, and performance venue installations
  • Drives balanced and unbalanced signals over long distances
  • Extra-high output at + 22 dBu
  • Provides galvanic isolation between input and output to eliminate hum caused by ground loops
  • Rejects noise by as much as 110 dB
  • Snaps into place onto a standard 35mm DIN rail for easy installation in a NEMA electrical enclosure
  • Jensen high-performance transformer
  • Flat frequency response from 2 Hz to 100 kHz
  • Handles signals in excess of +22 dB at 20 Hz without discernible distortion, with almost zero insertion loss
  • Choice of connection point options allows you to optimize grounding scheme to suit your installation
  • Connections to and from the module are made via removable screw-down wire terminals
  • Made from gray molded assembly made from UL94-VO flame retardant Noryl
  • Plug-and-play, easy to use, no power required

Jensen Transformers DIN-LOD Specs

TypePassive, line output isolator
Channels1
FormatFor standard 35 mm DIN rail in National Electrical Manufacturers Association (NEMA) electrical enclosure
ConnectorsRemovable, screw-down wire terminals
Frequency Response2 Hz to 100 kHz
Input Impedance20 Hz to 20 kHz, 0 dBu, test circuit 3
Minimum: 670 Ohms
Typical: 680 Ohms
Maximum: 690 Ohms
Voltage Gain1 kHz, 0 dBu, test circuit 1, Rs = 0 Ohm
Minimum: -1.2 dB
Typical: -1.1 dB
Maximum: -0.9 dB
Magnitude Response20 Hz, 0 dBu, test circuit 1, ref 1 kHz, Rs = 0 Ohm
Minimum: -0.10 dB
Typical: -0.02 dB
Maximum: ± 0.00 dB

20 kHz, 0 dBu, test circuit 1, ref 1 kHz, Rs = 0 Ohm
Minimum: -0.10 dB
Typical: ± 0.00 dB
Maximum: +0.10 dB
Deviation from Linear Phase20 Hz to 20 kHz, 0 dBu, test circuit 1, Rs = 0 Ohm
Typical: +0.3 / -0°
Maximum: ± 1.0°
BandwidthLF -3 dB re 1 kHz, test circuit 1, Rs = 0 Ohm
Typical: 0.10 Hz

HF -3 dB re 1 kHz, test circuit 1, Rs = 0 Ohm
Typical: 15 MHz
Distortion (THD)1 kHz, +4 dBu, test circuit 1, Rs = 0 Ohm
Typical: < 0.001%

20 Hz, +4 dBu, test circuit 1, Rs = 0 Ohm
Typical: 0.004%
Maximum: 0.03%
Maximum Output LevelAt 20 Hz, 1% THD, test circuit 1, Rs = 0 Ohm
Minimum: +20 dBu
Typical: +22 dBu
Common Mode Rejection Ratio60 Hz, test circuit 2
Typical: 110 dB

3 kHz, test circuit 2
Minimum: 75 dB
Typical: 85 dB
Output Impedance20 Hz to 20 kHz, 0 dBu, test circuit 4
Typical: 80 Ohms
Turn RatioMinimum: 0.999:1
Typical: 1.000:1
Maximum: 1.001:1
Optimal Cable LengthInput
Typical: 164` / 50 m
Maximum: 656` / 200 m

Output
No limitations
Temperature Range32 to 158°F / 0 to 70°C (operation or storage)
Voltage DifferenceWinding to Winding
Minimum: 250 V RMS (60 Hz, 1 minute test duration)

Winding to Frame
Minimum: 500 V RMS (60 Hz, 1 minute test duration)
ConstructionGray, molded assembly made from UL94-VO flame-retardant Noryl
Dimensions3.85 x 2.06 x 2.3" / 97.8 x 52.3 x 58.4 mm

Packaging Info

Package Weight1.02 lb
Box Dimensions (LxWxH)4.7 x 3.4 x 3.4"

In the Box

  • Jensen Transformers Iso-Max DIN-LOD 1-Channel Line Output Isolator (Extra-High Output, DIN Rail)
  • 2-Year Manufacturer Warranty

No posts found