Belden RG59 Plenum Cable (1000 , Black)
The black RG59 Plenum Cable (1000 ) from Belden features 20 AWG solid 0.03 (0.08cm) bare copper conductor, plenum, foam FEP insulation, Duofoil + tinned copper braid shield (95% coverage), and Flamarrest jacket.
The black RG59 Plenum Cable (1000 ) from Belden features 20 AWG solid 0.03 (0.08cm) bare copper conductor, plenum, foam FEP insulation, Duofoil + tinned copper braid shield (95% coverage), and Flamarrest jacket.
Belden 1506A-1000-BK Specs
Conductor | Number of Coax: 1 AWG: 20 Stranding: Solid Conductor Material: BC (Bare Copper) Diameter: 0.03" (0.06 cm) |
Insulation Material | Insulation Trade Name: Teflon Insulation Material: FFEP (Foam Fluorinated Ethylene Propylene) Diameter: 0.14" (0.33 cm) |
Outer Shield Material | Outer Shield Trade Name: Duofoil Type: Tape, Braid Outer Shield Material: Aluminum Foil Polyester, Tape Aluminum Foil, TC (Tinned Copper) Coverage (%): 100, 95 |
Outer Jacket Material | Outer Jacket Trade Name: Flamarrest Outer Jacket Material: PVC (Polyvinyl Chloride) |
Cable | Nominal Diameter: 0.2" (0.5 cm) |
Impedance | 75 © |
Inductance | 0.1 µH/feet |
Capacitance | Nominal Capacitance Conductor to Shield: 16.1 pF/feet |
Velocity of Propagation | 84% |
Conductor DC Resistance | 10 ©/1,000` at 68°F (20°C) |
Delay | 1.21 ns/feet |
Outer Shield DC Resistance | 3.2 ©/1,000` at 68°F (20°C) |
Maximum Voltage | 300 Vrms (UL) 18.0 kV (Nominal breakdown voltage between conductors) 16.9 kV (Nominal breakdown voltage conductors to shield) |
Return Loss | Start Frequency: 5 MHz, 1,600 MHz Stop Frequency: 1,600 MHz, 4,500 MHz Minimum RL (dB): 23, 21 |
Attenuation | Frequency (MHz): 1, Attenuation (dB/100`): 0.29 Frequency (MHz): 3.58, Attenuation (dB/100`): 0.62 Frequency (MHz): 5, Attenuation (dB/100`): 0.70 Frequency (MHz): 7, Attenuation (dB/100`): 0.82 Frequency (MHz): 10, Attenuation (dB/100`): 1.05 Frequency (MHz): 67.5, Attenuation (dB/100`): 2.20 Frequency (MHz): 71.5, Attenuation (dB/100`): 2.25 Frequency (MHz): 100, Attenuation (dB/100`): 2.70 Frequency (MHz): 135, Attenuation (dB/100`): 3.20 Frequency (MHz): 143, Attenuation (dB/100`): 3.25 Frequency (MHz): 180, Attenuation (dB/100`): 3.65 Frequency (MHz): 270, Attenuation (dB/100`): 4.55 Frequency (MHz): 360, Attenuation (dB/100`): 5.25 Frequency (MHz): 540, Attenuation (dB/100`): 6.4 Frequency (MHz): 720, Attenuation (dB/100`): 7.3 Frequency (MHz): 750, Attenuation (dB/100`): 7.5 Frequency (MHz): 1000, Attenuation (dB/100`): 9.4 Frequency (MHz): 1500, Attenuation (dB/100`): 12.8 Frequency (MHz): 2250, Attenuation (dB/100`): 17.5 Frequency (MHz): 3000, Attenuation (dB/100`): 21.9 |
Compliance | NEC/(UL) Specification: CMP CEC/C(UL) Specification: CMP EU Directive 2011/65/EU (ROHS II) EU CE Mark EU Directive 2000/53/EC (ELV) EU Directive 2002/95/EC (RoHS) EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005 EU Directive 2002/96/EC (WEEE) EU Directive 2003/11/EC (BFR) CA Prop 65 (CJ for Wire & Cable) MII Order #39 (China RoHS) RG Type: 59/U UL Flame Test: NFPA 262 |
Suitability | Indoor |
Plenum | Yes Non-Plenum Number: 1505A |
Temperature | Operating Temperature Range: -4 to 167°F (-20 to +75°C) Non-UL Temperature Rating: 167°F (75°C) |
Tension Control | Recommended Pulling Tension: 68.0 lb (30.8 kg) maximum |
Bend Radius | 2.0" (6.1 cm) |
Weight | 29.00 lb (13.15 kg) |
Packaging Info
Package Weight | 31 lb |
Box Dimensions (LxWxH) | 12.8 x 12.8 x 10.7" |
In the Box
- Belden RG59 Plenum Cable (1000`, Black)
- 2-Year Manufacturer Warranty